Leave Your Message
Instrumentation Cable EN 50288-7 – RE-2X(ST)HSWAH-TimF 14x3x1.5 Armored Screened Cable
Instrumentation Cable
Products Categories
Featured Products
Cable Customization

Instrumentation Cable EN 50288-7 – RE-2X(ST)HSWAH-TimF 14x3x1.5 Armored Screened Cable

Premium EN 50288-7 instrumentation cable RE-2X(ST)HSWAH-TimF 14x3x1.5mm².

CU/XLPE/ISCR/OSCR/LSZH/SWA/LSZH construction.

Triple configuration, dual screened, SWA armored. For process control and hazardous areas.

Request a detailed quote & datasheet!

  • Cable Type Instrumentation Cable RE-2X(ST)HSWAH-TimF EN 50288-7
  • Cable Spec 14x3x1.5mm²
  • Conductor CU plain copper (TC, CU, SPC, NPC optional)
  • Construction Stranded wire acc. to IEC 60228, Class 2
  • Insulation XLPE compound (PVC, PE, LSZH optional)
  • Cores/Pairs/Triads 12 triads twisted
  • Screen Individually and overally screen, aluminum foil and drainwire 120% coverage
  • Bedding LSZH compound (PVC optional) black
  • Armor SWA
  • Sheath LSZH compound (PVC optional) black
  • Rated Voltage 300/500V
  • Rated Temperature -30°C to +90°C
  • Basic Standard EN 50288-7
  • Flame Retardant IEC 60332-1-2, IEC 60332-3-24
  • Cable No. D596
  • Keyword armored instrumentation cable

Instrumentation Cable EN 50288-7 – Armored Screened CU/XLPE/ISCR/OSCR/LSZH/SWA/LSZH RE-2X(ST)HSWAH-TimF 14x3x1.5

This high-performance instrumentation cable features 14 triples of 1.5mm² in a fully armored and dual-screened construction, specifically engineered for critical signal transmission in industrial process plants, petrochemical facilities, and hazardous areas requiring robust mechanical protection and fire safety per EN 50288-7.

D596-14T-instrumentation-cable-armored-01-mini.jpg

Rated at 300/500V with operating temperature range of -30°C to +90°C, this cable is compliant with EN 50288-7 and meets fire performance standards including IEC 60332-1-2 and IEC 60332-3-24 .

Key Features & Technical Advantages

  • 14 triples x 1.5mm² for multi-channel three-wire instrumentation circuits

  • Bare copper Class 2 stranded conductors for conductivity and mechanical strength

  • XLPE insulation for low capacitance and high insulation resistance

  • Individual aluminium/polyester tape screen per triple eliminates crosstalk

  • Overall aluminium/polyester tape screen for external EMI protection

  • Tinned copper drain wires for continuous grounding

  • LSZH inner sheath and outer sheath for fire safety

  • SWA galvanized steel wire armour for mechanical protection

  • 300/500V rating, -30°C to +90°C operating range

  • Compliant with EN 50288-7, IEC 60332-1-2, IEC 60332-3-24

Why Choose This RE-2X(ST)HSWAH-TimF Instrumentation Cable

This 14-triple armored cable provides comprehensive protection for critical three-wire instrumentation signals. XLPE insulation ensures stable transmission, while individual and overall foil screens deliver dual-layer EMI protection. SWA armour guards against mechanical damage for direct burial and harsh environments. Dual LSZH sheaths ensure fire safety with low smoke and zero halogen emission. The triple configuration is specifically suited for three-wire RTD and sensor circuits requiring consistent conductor geometry.

Typical Applications – Solving Critical Instrumentation Challenges

  • Petrochemical Processing: Provides armored, fire-safe signal transmission for hazardous area instrumentation and control loops

  • Oil and Gas Facilities: Supplies mechanically protected cabling for wellhead control and pipeline monitoring

  • Distributed Control Systems (DCS): Enables reliable multi-channel I/O connections between field devices and control rooms

  • Hazardous Areas (ATEX): LSZH construction and armor suitable for Zone 1 and Zone 2 classified areas

FAQ

Q1: What does RE-2X(ST)HSWAH-TimF designation mean?

A: RE indicates instrumentation cable, 2X indicates XLPE insulation, (ST) indicates overall screen, H indicates LSZH sheath, SWA indicates steel wire armoured, H indicates LSZH outer sheath, TimF indicates triple configuration with individual and overall screens.

Q2: Why are triples used instead of pairs for this cable?

A: Triples (three conductors) are specifically suited for three-wire RTD and sensor circuits, providing consistent conductor geometry and accurate signal transmission for precision temperature measurement.

Q3: What is the advantage of SWA armour for instrumentation cables?

A: SWA provides exceptional mechanical protection against crushing, impact, and rodent attack, making the cable suitable for direct burial and harsh industrial environments without additional conduit.

Q4: What fire safety standards does this cable meet?

A: IEC 60332-1-2 (flame retardance) and IEC 60332-3-24 (reduced fire propagation), with LSZH construction ensuring low smoke and zero halogen emission.

Q5: What is the temperature range and voltage rating?

A: Operating temperature -30°C to +90°C, with 300/500V voltage rating per EN 50288-7.

TO POWER YOUR BRAND WITH US