Inquiry
Form loading...
PAS BS 5308 Part 2 Type 2 PVC/IS/OS/PVC/SWA/PVC Cable

Oil/Gas Industrial Cable

Products Categories
Featured Products
Cable Customization

PAS BS 5308 Part 2 Type 2 PVC/IS/OS/PVC/SWA/PVC Cable

Publicly Available Standard (PAS) BS 5308 cables are designed

to carry communication and control signals in a variety of

installation types including the petrochemical industry. The signals

can be analogue, data or voice type and from a variety of

transducers such as pressure, proximity or microphone. Part 2

Type 2 cables are designed where a greater degree of mechanical

protection is required namely outdoor / exposed or direct burial at

suitable depth. Individually screened for enhanced signal security.

    APPLICATION

    Publicly Available Standard (PAS) BS 5308 cables are designed
    to carry communication and control signals in a variety of
    installation types including the petrochemical industry. The signals
    can be analogue, data or voice type and from a variety of
    transducers such as pressure, proximity or microphone. Part 2
    Type 2 cables are designed where a greater degree of mechanical
    protection is required namely outdoor / exposed or direct burial at
    suitable depth. Individually screened for enhanced signal security.

    CHARACTERISTICS

    Rated Voltage :Uo/U: 300/500V

    Rated Temperature: 

    Fixed: -40ºC to +80ºC

    Flexed: 0ºC to +50ºC

    Minimum Bending Radius12D

    CONSTRUCTION

    Conductor

    0.5mm² - 0.75mm²: Class 5 flexible copper conductor

    1mm² and above: Class 2 stranded copper conductor

    Insulation: PVC (Polyvinyl Chloride)

    Individual and Overall Screen: Al/PET (Aluminium/Polyester Tape)
    Drain Wire: Tinned copper
    Inner Jacket:PVC (Polyvinyl Chloride)
    Armour:SWA (Galvanised Steel Wire Armour)
    Sheath:PVC (Polyvinyl Chloride)
    Sheath Colour: Blue Black

    图片 30图片 31
    companydniexhibitionhx3packingcn6processywq

    Introduction to BS 5308 Part 2 Type 2 PVC/IS/OS/PVC/SWA/PVC Cable
    I. Overview
    The BS 5308 Part 2 Type 2 PVC/IS/OS/PVC/SWA/PVC Cable is a significant product in the field of communication and control signal transmission. It is designed to meet the requirements of diverse installation scenarios, especially in the petrochemical industry, while also offering a range of features for reliable performance.
    II. Application
    Signal Transmission
    This cable is engineered to carry various types of signals, including analogue, data, and voice signals. Signals from a variety of transducers such as pressure sensors, proximity detectors, and microphones can be effectively transmitted. This versatility makes it suitable for a wide array of communication and control systems, providing seamless connectivity in different technological setups.
    Petrochemical Industry and Beyond
    In the petrochemical industry, where safety and efficiency are of utmost importance, this cable plays a vital role. It can be used in different installations within the industry to ensure reliable signal transfer for critical processes.
    Mechanical Protection Requirements
    Part 2 Type 2 cables are specifically designed for situations where a greater degree of mechanical protection is needed. This includes outdoor or exposed installations and direct burial at a suitable depth. In outdoor settings, the cable may be exposed to various environmental factors such as weather, physical impact, or abrasion. The ability to be directly buried also makes it suitable for underground installations where it must withstand soil pressure and potential damage from underground elements.
    Signal Security
    The individually screened design of the cable enhances signal security. In environments where signal integrity is crucial, such as in industrial control systems or communication networks, this feature ensures that the transmitted signals are protected from interference, maintaining the accuracy and reliability of the data or communication.
    III. Characteristics
    Rated Voltage
    With a rated voltage of Uo/U: 300/500V, the cable is well - suited for many common electrical applications related to communication and control signal transfer. This voltage rating allows it to function within a standard range, providing a stable power supply for the signals it carries.
    Rated Temperature
    The cable has a rated temperature range that varies depending on its state. For fixed installations, it can operate within a temperature range of - 40ºC to +80ºC, while for flexed conditions, the range is from 0ºC to +50ºC. This wide temperature tolerance enables it to be used in diverse climates and environments, from extremely cold to relatively hot conditions.
    Minimum Bending Radius
    A minimum bending radius of 12D is specified for this cable. This characteristic is important during installation as it determines how much the cable can be bent without causing damage to its internal structure. It allows for flexibility in routing the cable in different installation layouts.
    IV. Construction
    Conductor
    For cross - sectional areas between 0.5mm² - 0.75mm², the cable utilizes Class 5 flexible copper conductors. These conductors offer excellent flexibility, which is beneficial in applications where the cable may need to be bent or moved. For areas of 1mm² and above, Class 2 stranded copper conductors are used. These provide good conductivity and mechanical strength, ensuring efficient signal transmission and durability.
    Insulation
    The PVC (Polyvinyl Chloride) insulation used in this cable provides electrical insulation. PVC is a cost - effective and commonly used material for cable insulation, helping to prevent electrical leakage and ensure the integrity of the transmitted signals.
    Screening
    The individual and overall screen made of Al/PET (Aluminium/Polyester Tape) offers protection against electromagnetic interference. This is crucial for maintaining the quality of the transmitted signals, especially in environments with potential sources of electromagnetic noise.
    Drain Wire
    The tinned copper drain wire serves to dissipate any electrostatic charges that may accumulate on the cable. This helps in enhancing the safety and performance of the cable by preventing static - related issues.
    Inner Jacket, Armour, and Sheath
    The inner jacket, made of PVC, provides an additional layer of protection to the internal components of the cable. The SWA (Galvanised Steel Wire Armour) offers strong mechanical protection, safeguarding the cable from external forces such as crushing, impact, or abrasion. The outer sheath, also made of PVC, further protects the cable and has a sheath colour of blue - black, which aids in easy identification during installation.
    In conclusion, the BS 5308 Part 2 Type 2 PVC/IS/OS/PVC/SWA/PVC Cable is a well - designed cable with a combination of features that make it suitable for a variety of applications. Its ability to carry different types of signals, withstand different environmental conditions, and provide mechanical and signal protection makes it a reliable choice in industries such as the petrochemical industry and in various communication and control systems.