Yintoni iCable yeAlarm yoMlilo eKhuselekileyo ngaphakathi?
- Umngeni Okhethekileyo: Ukufumanisa Imililo Ngaphandle Kokuyibangela
Iinkqubo zesilumkiso somlilo zijongene nemeko engaqhelekanga kwiindawo ezinobungozi. Kufuneka zibone umlilo ngokuthembekileyo—kodwa akufuneki zenze umthombo wokutsha oqala umlilo kwasekuqaleni.
Kwiindawo zokucoca iikhemikhali, kwiindawo zokucoca ioyile, kwiindawo zokugcina amafutha, kwiindawo zokucoca igesi, nakwiindawo zokutshiza ipeyinti, umoya uneegesi ezivuthayo, umphunga, okanye uthuli oluvuthayo. Intambo yesilumkiso somlilo eqhelekileyo, ukuba yonakele okanye imfutshane, inokuvelisa intlantsi ekwaziyo ukutshisa umoya onobungozi ongqongileyo.
Intambo yesilumkiso somlilo esikhuselekileyo (IS) isombulula le ngxaki ngokudibanisa izinto ezimbini ezibalulekileyo:
| Uphawu | Injongo | Inzuzo |
| Umlinganiselo wamandla (Ukhuseleko lwangaphakathi) | Inciphisa amandla ombane kwintambo ukuze ingabi nokubangela ukutsha | Kukhuselekile ukuyifaka nokusebenza kwiindawo ezinobungozi zeZone 0/1/2 |
| Ukunyaniseka kweSekethe (Ukusinda koMlilo) | Igcina umsebenzi wesekethe ngexesha lomlilo wokwenyani | Iialamu ziyasasazeka nangona ezinye iinkqubo zingasebenzi — ukhuseleko lobomi |
KwiDingzun Cable,Iintambo zethu zesilumkiso somlilo ezikhuselekileyo ngokwendalo zenzelwe ukhuseleko lweendawo ezinobungozi kunye nokusinda emlilweni, ziqinisekiswe ngokwemigangatho yamazwe ngamazwe yezicelo zepetrochemical, amayeza kunye nemizi-mveliso.
- Indlela Esebenza Ngayo: Ukulinganiselwa Kwamandla + Ukunyaniseka Kwesekethe
Inkqubo yesilumkiso somlilo ekhuselekileyo ngokwendalo iqulathe izinto ezintathu ezisebenzisanayo.

(Umzobo wenkqubo ye-alamu yomlilo ekhuselekileyo ngokwendalo)
Itheyibhile 1: Izixhobo zeNkqubo ye-IS Fire Alarm
| Icandelo | Indawo | Umsebenzi | Umzekelo |
| Umqobo we-IS(I-Zener okanye i-Galvanic Isolator) | Indawo Ekhuselekileyo (Igumbi Lolawulo) | Inciphisa i-voltage, i-current, kunye namandla ukuya kumanqanaba akhuselekileyo — ngesiqhelo | Ithintela isekethe yesilumkiso somlilo ekuveliseni intlantsi ekwaziyo ukutsha |
| Intambo ye-Alarm yoMlilo yi-IS | Indawo Enobungozi (Indawo 1/2) | Ithumela amandla alinganiselweyo ngelixa igcina ukuthembeka kwesekethe ngexesha lomlilo | Intambo eluhlaza okwesibhakabhaka, enesheya ye-LSZH, enexabiso le-FE180 |
| IS Fire Detector(umz., Ukufunyanwa koBushushu obuLungileyo) | Indawo enobungozi | Ibona umlilo ngaphandle kokudala umngcipheko wokutsha | Ihlelwe njenge "sixhobo esilula" ngokwe-IEC 60079-11 |
Umgaqo Wokuncitshiswa Kwamandla:
Nokuba intambo ngokwayo inomqobo ofanelekileyo othintela amandla ukuya ku-umthamo (Cc)kwayeinductance (Lc)Intambo ye-IS eqinisekisiweyo ye-alamu yomlilo inexabiso eliphantsi le-Cc kunye ne-Lc ukuqinisekisa ukuba naphantsi kweemeko zempazamo, amandla agciniweyo awanakubangela ukutsha.
Umgaqo woBulungisa beSekethe:
Ngexesha lomlilo wokwenyani, iintambo eziqhelekileyo ziyanyibilika, zikhawuleze ukusebenza, okanye zivuleke kwimizuzu embalwa. Intambo yesilumkiso somlilo eneukuthembeka kwesekethe (CI)umlinganiselo uyaqhubeka nokusebenza ixesha elithile (imizuzu engama-30 ukuya kweli-180 nangaphezulu) — ukuqinisekisa ukuba ii-alamu zifikelela kwiphaneli yokulawula nangona umlilo usasazeka.
KwiDingzun Cable,Iintambo zethu ze-IS ze-alamu yomlilo ziyilwe nge-Cc/Lc parameters eziphantsi (zokhuseleko lwendawo enobungozi) kunye nezixhobo zobushushu obuphezulu (zokusinda emlilweni).
- Uvavanyo loBulungisa beSekethe: FE180, E30, nangaphaya
Uvavanyo lokuthembeka kwesekethe luchaza ukuba intambo iya kuhlala isebenza ixesha elingakanani ngexesha lokuvezwa ngumlilo.
Itheyibhile 2: Uvavanyo loBulungisa beSekethe yeCable Alarm yoMlilo
| Uvavanyo | Umgangatho | Ukuvezwa koMlilo | Ubude bexesha | Isicelo esiqhelekileyo |
| FE180 | I-IEC 60331 / BS 6387 | 750-950°C (ilangatye elithe ngqo) | imizuzu eli-180 | Ukhuseleko oluphezulu — iindlela zokubaleka, iisekethe ezibalulekileyo ze-alamu kwizityalo ze-petrochemical |
| E30 | I-DIN 4102-12 | 800°C (ijika lomlilo eliqhelekileyo) | imizuzu engama-30 | Iisekethe ze-alamu yomlilo ngokubanzi, ukhuseleko oluphakathi |
| E60 | I-DIN 4102-12 | 800°C (ijika lomlilo eliqhelekileyo) | imizuzu engama-60 | Ukhuseleko oluphuculweyo lwezakhiwo ezisetyenziswa ngabantu |
| E90 | I-DIN 4102-12 | 800°C (ijika lomlilo eliqhelekileyo) | imizuzu engama-90 | Izakhiwo ezinde, iziseko ezibalulekileyo |
| CWZ | BS 6387 | 950°C + isitshizi samanzi + umatshini wokutshiza | Iyahluka | Iimeko ezinzima kakhulu (iitonela, amaqonga aselunxwemeni) |
Oko Kuthethwa ZiiNgqikelelo:
| Uvavanyo | Oko Kuqinisekisayo | Indlela yoVavanyo |
| FE180 | Intambo igcina umbane uqhubeka imizuzu eli-180 phantsi komlilo othe ngqo kwi-750-950°C | I-IEC 60331-21 |
| E30/E60/E90 | Intambo igcina ukuthembeka kwesekethe imizuzu engama-30/60/90 phantsi kwegophe lomlilo eliqhelekileyo | I-DIN 4102-12 |
| I-LSZH | Umsi ophantsi, akukho halogen — igesi enobuthi kunye nomsi omncinci ngexesha lomlilo | I-IEC 61034, IEC 60754 |
Isikhokelo Sokukhetha Iindawo Eziyingozi:
| Isicelo | Ireyithingi Ecetyiswayo | Ingqiqo |
| Indawo yokucocisa ioyile — i-alamu ebalulekileyo | FE180 | Ixesha elide lokusinda; ikhusela iindlela zokubaleka |
| Isityalo sekhemikhali — isilumkiso esiqhelekileyo | E60okanyeE90 | Ibhalansi yeendleko kunye nokhuseleko |
| Iziko lezonyango | E30+ LSZH | Ukusinda emlilweni + ukhuseleko lomsi |
| Iqonga laselunxwemeni | CWZ(BS 6387) | Iyamelana nelangatye + isitshizi samanzi + ukutshixwa koomatshini |
KwiDingzun Cable,senza iintambo ze-IS ze-alamu yomlilo ngeFE180,E30,E60kunyeE90ukulinganiswa — konke oku kufakwe i-LSZH sheathing yokukhupha umsi omncinci kunye nokukhupha i-halogen engekhoyo.
- Ukwakhiwa kwentambo ye-alamu yomlilo ekhuselekileyo ngaphakathi
Iintambo ze-IS ze-alamu yomlilo zinezakhiwo ezikhethekileyo ukuhlangabezana neemfuno zokusinda kwindawo enobungozi kunye nokusinda emlilweni.

(Intambo ye-IS eluhlaza okwesibhakabhaka)
Itheyibhile 3: Ukwakhiwa kwentambo ye-IS Fire Alarm
| Icandelo | Inkcazo yeCable yeAlarm yoMlilo ye-IS | Injongo |
| Umqhubi | Ubhedu olufakwe kwisitya olunezinti eziqinileyo (Udidi 5/6) | Ukuguquguquka; ukumelana nokugqwala; isignali ethembekileyo ngexesha lomlilo |
| Ukuvala ubushushu | Iteyiphu yeglasi yeMica+ XLPE okanye i-FEP | I-Mica ibonelela ngokusinda emlilweni (uthuthu lwe-silica luhlala lukhusela); i-XLPE/FEP ibonelela ngeempawu zombane |
| Isibini esijijekileyo | Ewe (ukungavumi ingxolo) | Inciphisa ukuphazamiseka kwe-EMI kwiindawo zoshishino |
| Ukukhusela | I-braid yobhedu efakwe kwi-tin iyonke(≥85% yokugubungela) | Iibhloko ze-EMI; zibonelela ngokhuseleko loomatshini |
| Ucingo lokukhupha amanzi | Ifakiwe (ithusi elifakwe ebhotileni) | Yenza kube lula ukuseka isiseko sendawo enye |
| Ijakethi yangaphakathi | I-LSZH okanye i-compound engenamsi uphantsi | Ukhuseleko lomlilo; kuthintela ukungena komswakama |
| Isikrweqe(ukhetho) | Isikhuselo sentsimbi yentsimbi (GSWA) okanye i-aluminium evaliweyo | Ukukhuselwa ngoomatshini kwiindawo zokungcwaba ngokuthe ngqo okanye ezinobungozi obukhulu |
| Isingxobo sangaphandle | Oluhlaza okwesibhakabhaka (RAL 5015) LSZH | Ukuchonga i-IS okunyanzelekileyo ngokwe-IEC 60079-14; umsi ophantsi, akukho halogen |
| Uvavanyo loMlilo | FE180(Imizuzu eli-180),E30/E60/E90 | Ukuthembeka kwesekethe ngexesha lomlilo |
| Ukuthobela i-IS | I-Ex-ia okanye i-Ex-ib ngokwe-IEC 60079-11 | Ukunqongophala kwamandla kwiindawo ezinobungozi |
Kutheni iMica Tape ibalulekile ekusindeni komlilo:
| Izinto eziphathekayo | Ukuziphatha Ngexesha Lomlilo | Isizathu Sokuba Kubalulekile |
| Iteyiphu yeMica | Yenza uthuthu lwe-silica olungahambisi umbane (luhlala lukhusela ubushushu) | Isekethe ihlala isebenza nangona intambo itsha |
| I-PVC | Iyanyibilika, i-carbonizes, ibe yi-conductor | Isekethe emfutshane iyenzeka; i-alamu ayisebenzi |
| I-XLPE | Iyatshisa, ishiya intsalela eqhubayo | Isekethe iyasilela |
| I-silicone | Yenza uthuthu olungahambisi moya (olulungileyo) kodwa amandla angaphantsi koomatshini | Yamkelekile kodwa ayixhaphakanga kakhulu xa kuziwa kwi-alamu yomlilo |
KwiDingzun Cable,Iintambo zethu ze-IS ze-alamu yomlilo ezisetyenziswayoubushushu obuneeleya ezimbini— iteyiphu yeglasi ye-mica yokusinda emlilweni kunye ne-XLPE okanye i-FEP yokusebenza kombane — ukuqinisekisa ukuthembeka kwesekethe ngexesha lomlilo ngelixa kuhlangatyezwana neemfuno ze-IS ezinomthamo ophantsi.
- Ukufunyanwa koBushushu obuLinear (LHD) njengeSixhobo esilula
Iintambo zokubona ubushushu ezithe tyaba zihlala zisetyenziswa njengezixhobo zokubona umlilo kwiindawo ezinobungozi. Phantsi kwe-IEC 60079-11, zinokuhlulwahlulwa njenge"isixhobo esilula"— zichazwa njengezixhobo ezingavelisi okanye ezingagcini ngaphezu kwe-1.2V, 0.1A, 25mW, okanye 20µJ.
Indlela Esebenza Ngayo Ukufumanisa Ubushushu Obuhamba Ngemigca:
| Icandelo | Umsebenzi |
| Intambo ye-LHD | Ii-conductor ezimbini ezijijekileyo ezahlulwe yi-polymer evakalelwa bubushushu. Xa ubushushu bufikelela kumda, i-polymer iyanyibilika, ii-conductor ziqhagamshelane, kwaye i-alamu iyabangela |
| Umqobo we-IS | Inciphisa amandla ukuya kumanqanaba akhuselekileyo |
| Iphaneli yokulawula | Ijonga ukumelana nesekethe; ivuselela i-alamu kwisekethe emfutshane |
Kutheni i-LHD ifanelekile kwiindawo ezinobungozi:
- Ukusebenza okungasebenziyo— Akukho zixhobo ze-elektroniki ezisebenzayo kwindawo enobungozi
- Amandla anqongophele— Xa iqhagamshelwe nge-IS barrier, isekethe ayinakuvelisa i-spark ekwaziyo ukutsha
- Ikhuselekile— Isekethe evulekileyo okanye isekethe emfutshane zombini zivelisa i-alamu (ijongiwe)
KwiDingzun Cable,sinikezelaIintambo zokuchonga ubushushu ezingqinisisiweyo yi-ISyokubeka esweni umlilo kwindawo enobungozi, ehambelana nezithintelo ze-IS eziqhelekileyo kunye neepaneli zolawulo.
- Iinkcukacha kunye neMigangatho yokuThotyelwa kweMithetho
Iintambo ze-IS ze-alamu yomlilo kufuneka zihlangabezane nemigangatho emininzi yokhuseleko lweendawo ezinobungozi, ukusinda emlilweni, kunye nokukhutshwa komsi okuphantsi.
Itheyibhile 4: Intambo ye-IS Fire Alarm — Imigangatho yokuthobela imithetho
| Umgangatho | Imfuneko | Iinkcukacha zeSihluthulelo |
| I-IEC 60079-11 | Ukhuseleko lwangaphakathi | I-Ex-ia (iZone 0/1) okanye i-Ex-ib (iZone 1) — iiparameter ze-Cc/Lc ezibhaliweyo |
| I-IEC 60079-14 | Ukufakelwa kwiindawo ezinobungozi | Ukuchongwa okuluhlaza okwesibhakabhaka (RAL 5015) |
| I-IEC 60331-21 | Ukuthembeka kwesekethe phantsi komlilo | FE180— imizuzu eli-180 kwi-750-950°C |
| I-DIN 4102-12 | Ukuthembeka kwesekethe phantsi komlilo | E30/E60/E90— imizuzu engama-30/60/90 |
| I-IEC 61034 | Uxinano lomsi | I-LSZH — ukukhutshwa komsi okuphantsi |
| I-IEC 60754 | Umxholo weHalogen | I-halogen ye-zero (akukho HCl okanye iigesi ezinobuthi) |
| I-IEC 60332-1 | Ukulibaziseka kwelangatye | Ukuzicima ngokwakho |
| I-IEC 60092-502 | Ukhuseleko loomatshini | Isingxobo se-LSZH esiqinileyo |
Isishwankathelo seenkcukacha ezibalulekileyo:
| Ipharamitha | Ixabiso lekhebula le-IS Fire Alarm |
| Uvavanyo lwe-IS | I-Ex-ia (iZone 0/1) okanye i-Ex-ib (iZone 1) |
| Ukusinda koMlilo | FE180 (imizuzu eli-180), E30/E60/E90 |
| Umbala weSheath | Oluhlaza okwesibhakabhaka (RAL 5015) |
| Izinto zeSingxobo | I-LSZH (umsi ophantsi ongenalo i-halogen) |
| Ukuvala ubushushu | Iteyiphu yeMica + XLPE/FEP |
| Ukukhusela | Ukuluka kobhedu okufakwe ebhotileni (≥85%) |
| Umqhubi | Ubhedu olufakwe kwi-tin |
| Uluhlu lobushushu | -40°C ukuya ku +90°C (eqhelekileyo) |
| Uvavanyo lweLanga | I-IEC 60332-1, IEC 60332-3 |
KwiDingzun Cable,Iintambo zethu ze-IS ze-alamu yomlilo ziqinisekisiwe ngokupheleleyo kule migangatho — kunye neengxelo zovavanyo ezibhaliweyo ezibonelelwayo kuyo yonke impahla ethunyelwayo.
- Izicelo eziqhelekileyo zeentambo ze-IS Fire Alarm
Iintambo ze-IS ze-alamu yomlilo zichaziwe ukuze kufunyanwe umlilo kwindawo enobungozi kumashishini amaninzi.
Itheyibhile 5: Ii-IS Fire Alarm Cable Applications ngokweShishini
| Ishishini | Indawo enobungozi | Isicelo esiqhelekileyo | Iireyithingi ezifunekayo |
| Iivenkile zeoyile negesi/zokucoca | Indawo 1/2 | Ukufunyanwa komlilo kwindawo yenkqubo, ii-alamu zokuvala ungxamiseko (ESD) | I-Ex-1, FE180, LSZH |
| Ukucubungula iikhemikhali | Indawo 1/2 | Ukufunyanwa kobushushu kwindawo ye-reactor, iisekethe ze-alamu zegumbi lolawulo | I-Ex-ib, E60/E90, LSZH |
| Amayeza | Indawo 1 (iindawo ezinyibilikisa amanzi) | Ukubeka iliso kumlilo kwigumbi lokucoca, ukufunyanwa kwendawo yokugcina isinyibilikisi | I-Ex-1, E30, LSZH |
| Indawo yokugcina amafutha (iifama zetanki) | Indawo 1/2 | Ukufunyanwa komlilo we-rim seal yetanki, ii-alamu zendlu yepompo | I-Ex-ia, FE180, LSZH |
| Iibhuthi zepeyinti/zokutshiza | Indawo 1 | Ukufunyanwa komlilo webhokisi, ukujonga inkqubo yokukhupha umbane | I-Ex-1, E30, LSZH |
| Ukucubungula iGesi / i-LNG | Indawo 1/2 | Ukufunyanwa kwendawo yecompressor, ukujonga umlilo wepayipi | I-Ex-1, FE180, LSZH |
| Amanzi amdaka (Izakhiwo zeDigester) | Indawo 1 | Ukufunyanwa komlilo kwindawo yeMethane | I-Ex-1, E30, LSZH |
| Amaqonga aselunxwemeni | Indawo 1/2 | Ukufunyanwa komlilo kunye ne-alamu yeqonga elipheleleyo | I-Ex-ia, CWZ (BS 6387), LSZH |
KwiDingzun Cable,Sinikezele ngeentambo ze-IS ze-fire alarm kwiiprojekthi kuzo zonke ezi shishini. Iqela lethu lobunjineli liyaqonda iimfuno ezithile zecandelo ngalinye kwaye linokucebisa ukwakhiwa kweentambo ezifanelekileyo kwisicelo sakho.
- Isikhokelo soKhetho: Ukukhetha intambo ye-alamu yomlilo eyiyo eyiyo
Sebenzisa olu luhlu xa uchaza iintambo ze-alamu yomlilo ezikhuselekileyo ngokwendalo kwiindawo ezinobungozi.
Itheyibhile 6: Uluhlu lokujonga ukukhethwa kwentambo ye-IS Fire Alarm
| Ipharamitha | Imfuneko Yakho | Iinketho zeDingzun |
| Ulwahlulo lweNdawo enobungozi | Indawo 0 / Indawo 1 / Indawo 2 | I-Ex-ia (iNdawo 0/1), i-Ex-ib (iNdawo 1) |
| Ixesha Lokusinda Emlilweni Liyafuneka | Imizuzu engama-30 / imizuzu engama-60 / imizuzu engama-90 / imizuzu eli-180 | E30, E60, E90, FE180 |
| Inqanaba lokuvezwa lilangatye/bubushushu | Esemgangathweni / Eqatha | I-FE180 yokuvezwa kakhulu (imizuzu eli-180 kwi-950°C) |
| Imfuneko yokukhupha umsi | Umsi ophantsi uyafuneka? | I-LSZH (umsi ophantsi ongenalo i-halogen) — eqhelekileyo |
| Ngaba kufuneka i-halogen ingabikho? | Ewe Hayi | I-LSZH (zero halogen) - umgangatho |
| Ukhuseleko lweMishini | Umngcwabo ngqo / Itreyi yekhebula / Umjelo | Yongeza isikrweqe se-GSWA ukuze ungcwatywe ngqo |
| Inani labaQhubi | 2 / 4 / 6 / Ngakumbi | Abaqhubi abangaphezulu kwe-2 ukuya kwi-100 |
| Igeyiji yoMqhubi | I-AWG _____ | 18-24 AWG eqhelekileyo |
| Kufuneka Ukhuseleko? | Ewe Hayi | Ukuluka kobhedu okufakwe ebhotileni (≥85%) — kucetyiswa kwi-industrial EMI |
| Ukuvezwa Ngaphandle / kwi-UV | Ewe Hayi | I-LSZH ezinzileyo nge-UV iyafumaneka |
| Ikhowudi yoMbala | Oluhlaza okwesibhakabhaka (RAL 5015) | Oluhlaza okwesibhakabhaka olukhanyayo (RAL 5015) — iyimfuneko ngokwe-IEC 60079-14 |
KwiDingzun Cable,Iqela lethu lobunjineli linokukunceda ukhethe intambo ye-IS efanelekileyo ye-alamu yomlilo ngokusekelwe kuhlu lweendawo ezinobungozi, ixesha lokusinda komlilo elifunekayo, kunye neemeko zokusingqongileyo.
Malunga neDingzun Cable: Iqabane lakho leCable yeAlarm yoMlilo ekhuselekileyo ngokwendalo
NgeIminyaka engama-20+ yamava akhethekileyo okuvelisa,Intambo yeDingzunliqabane elithembekileyo lehlabathi le-oyile negesi, iikhemikhali, amayeza, kunye nezakhiwo zoshishino ezifuna isiqinisekisoIintambo ze-alamu yomlilo ezikhuselekileyo ngaphakathi (IS)ukuchonga umlilo kwindawo enobungozi. Sidibanisa ubuchule obunzulu bendawo enobungozi kunyeukwenza ngokwezifiso okukhuluukuhambisa iintambo ezibonelela ngokuthintela ukutsha kunye nokusinda emlilweni.

(Ukuveliswa kweCable yeDingzun Cable eKhuselekileyo yoMlilo)
Amandla ethu ekhebula le-IS Fire Alarm:
| Ubuchule | Iinkcukacha zeDingzun |
| Ukuthobela i-IS | IEC 60079-11, IEC 60079-14 — Ex-ia (Indawo 0/1), Ex-ib (Indawo 1) |
| Amanqaku okusinda emlilweni | FE180(Imizuzu eli-180, IEC 60331),E30/E60/E90(DIN 4102-12) |
| Umbala weSheath | Oluhlaza okwesibhakabhaka (RAL 5015)— inyanzelekile ngokwe-IEC 60079-14 |
| Izinto zeSingxobo | I-LSZH(umsi ophantsi akukho halogen) — umgangatho |
| Ukuvala ubushushu | Iteyiphu yeglasi yeMica+ XLPE okanye i-FEP |
| Ukukhusela | I-copper braid efakwe kwi-tin(≥85% yogqumo) + ucingo lokukhupha amanzi |
| Umqhubi | Ubhedu olufakwe kwisitya olunezinti eziqinileyo (Udidi 5/6) |
| Isikrweqe(ukhetho) | I-GSWA (isikhuselo sentsimbi yentsimbi) sokukhusela oomatshini |
| Iiparameter zoMbane | I-Cc kunye ne-LC eziqinisekisiweyokubalo lwezinto |
| Uluhlu lobushushu | -40°C ukuya ku +90°C (eqhelekileyo) |
| Uvavanyo lweLanga | I-IEC 60332-1, IEC 60332-3 |
| Iziqinisekiso | ISO 9001:2015, CE, RoHS, REACH |
| Uvavanyo | Uvavanyo lombane oluyi-100%kuyo yonke ireyile |
Kutheni iDingzun Cable yesicelo sakho se-IS Fire Alarm:
- Ukugxila kukhuseleko oluphindwe kabini— Ukunciphisa amandla (kuthintela ukutsha) + ukuthembeka kwesekethe (kusinda emlilweni)
- Ukwenziwa ngokwezifiso okukhulu— Ubude, inani lomqhubi, igeyiji, isikrweqe, ukuprinta okwenziwe ngokwezifiso
- Umgangatho we-LSZH— Umsi ophantsi, akukho halogen — ukhuseleko emlilweni ngaphandle kokukhutshwa kwetyhefu
- Ukuchongwa okuluhlaza okwesibhakabhaka okukhanyayo— I-RAL 5015 sheath enophawu lwe-Ex-ia/Ex-ib ngokwe-IEC 60079-14
- Iqela leengcali zobunjineli— Inkxaso yokubala izinto, ukufanisa imiqobo, kunye noyilo lwenkqubo
- Amaxwebhu apheleleyo— Iingxelo zovavanyo, izatifikethi zokuthobela imithetho, kunye nokulandelelwa
Ngaba ufuna intambo yesilumkiso somlilo ekhuselekileyo eyenzelwe indawo yakho enobungozi?