Premium high voltage silicone shielded cable 60kVDC 4mm².

TC tinned copper 56/0.30 conductor, tear resistant SiR insulation. Double TCWB braid shield. Red PVC sheath. 18mm O.D.

Request a detailed quote & datasheet!

  • Cable Type 60kVDC silicone cable
  • Cable Spec 4mm²
  • Conductor TC tinned copper (TC, CU, SPC, NPC optional)
  • Construction Stranded wire 56/0.30 acc. to IEC 60228, Class 5
  • Insulation Special silicone flexible compound (FEP, PTFE, PFA, PI, PEEK optional)
  • Binder Polyster tape
  • Screen SCR double tinned copper wire braid shielding
  • Sheath Red PVC compound (FEP, PTFE, PFA, PI, PEEK optional)
  • O.D. 18mm
  • Rated Voltage 60KV DC
  • Cable No. D359
  • Keyword high voltage shielded cable
  • Application ideal for High Voltage Testing Equipment, X-Ray Equipment Power Supply

High Voltage Silicone Shielded Cable 60kVDC 4mm² TC/SiR/SCR/PVC – TC Tinned Copper Conductor 56/0.30, Tear Resistant Silicone Rubber Insulation 13.5mm Wire Diameter, Polyester Tape Binder, SCR Double Tinned Copper Wire Braid Shielding, Red PVC Sheath, 18mm Outer Diameter

This high voltage silicone shielded cable is engineered for 60kVDC applications requiring reliable insulation and comprehensive shielding. The TC tinned copper conductor features 56/0.30 fine-strand construction, providing flexibility and corrosion resistance. The primary insulation consists of tear resistant silicone rubber compound with 13.5mm wire diameter, engineered to withstand 60kVDC without breakdown while maintaining flexibility. A polyester tape binder ensures mechanical stability and protects the insulation during shielding application. The SCR shielding comprises double tinned copper wire braiding, providing two layers of EMI protection and enhanced safety for high voltage applications. The red PVC sheath offers durability, UV resistance, and high-visibility identification for high voltage circuits. With 18mm outer diameter, this cable delivers robust performance in demanding high voltage environments.

D359-high-voltage-silicone-shielded-60kvdc-4mm2-02.jpgD359-high-voltage-silicone-shielded-60kvdc-4mm2-03.jpg

Key Features & Technical Advantages

  • 60kVDC rated with tear resistant silicone insulation 13.5mm diameter

  • TC tinned copper 56/0.30 fine-strand conductor for flexibility

  • SCR double tinned copper wire braid shielding for maximum EMI protection

  • Polyester tape binder for mechanical stability

  • Red PVC sheath for high voltage identification

  • 18mm outer diameter robust construction

Specifications & Construction

Parameter Details
Voltage Rating 60kVDC
Conductor TC tinned copper 56/0.30
Insulation Tear resistant SiR rubber, 13.5mm wire dia.
Binder Polyester tape
Shield SCR double TCWB braid
Sheath PVC compound red
Outer Diameter 18mm

Why Choose Our 60kVDC Silicone Shielded Cable

We specialize in high voltage cable technology for demanding applications. Our 60kVDC design combines tear resistant silicone insulation with double TCWB braid shielding for maximum safety and performance. The 56/0.30 fine-strand conductor ensures flexibility for installation, while the 13.5mm insulation thickness provides reliable 60kVDC withstand capability. Double braid shielding offers redundant EMI protection and enhanced safety. Red PVC sheath ensures immediate high voltage identification. As a specialized manufacturer, we control all production stages, offering custom lengths and technical support for your specific high voltage requirements.

D359-high-voltage-silicone-shielded-60kvdc-4mm2-01.jpg

Typical Applications – Solving Critical Industrial Challenges

  • X-Ray Equipment Power Supply: Eliminates insulation breakdown in medical X-ray generators requiring stable 60kVDC delivery with comprehensive safety shielding

  • Electrostatic Precipitators: Provides reliable high voltage connections for industrial air pollution control systems operating continuously at 60kVDC

  • Particle Accelerator Systems: Delivers stable DC power to research and medical accelerator components where voltage stability and safety are critical

  • High Voltage Testing Equipment: Ensures safe, reliable connections for cable testers and insulation testers operating at 60kVDC

  • Industrial Laser Power Supplies: Maintains consistent high voltage delivery to laser generators in manufacturing and medical applications

  • Capacitor Charging Systems: Provides dependable high voltage connections for pulse power and energy storage applications

  • Scientific Research Instruments: Delivers clean 60kVDC power to laboratory equipment requiring stable high voltage with minimal interference

FAQ

Q1: Why is silicone rubber chosen for 60kVDC insulation?

A: Silicone rubber offers exceptional dielectric strength, flexibility, and tear resistance, maintaining insulating properties at high voltages while allowing installation flexibility impossible with rigid insulation materials.

Q2: What is the advantage of double TCWB braid shielding?

A: Double braid shielding provides redundant EMI protection, enhanced safety for high voltage applications, and improved mechanical strength compared to single braid constructions.

Q3: What does the 13.5mm insulation thickness provide?

A: The 13.5mm silicone insulation thickness is engineered specifically for 60kVDC withstand capability, providing the dielectric strength necessary for reliable long-term performance at this voltage level.

Q4: Why is the sheath color red?

A: Red is internationally recognized for high voltage cable identification, ensuring immediate visual recognition of 60kVDC circuits for safety during installation and maintenance.

Q5: Is this cable suitable for outdoor installation?

A: The red PVC sheath provides UV resistance for outdoor installation. However, for direct burial or extreme environmental exposure, please consult our engineering team for additional protection options.