Leave Your Message
I-LNG Terminal Header kunye neCryogenic Cable – I-CU/PEEK Cable 7mm² 0.6/1.0kV (6/10kV Ukhetho) Ukumelana nobushushu obuMthubi obuneMilo yesikwere 300°C
Intambo Yesiko
Iindidi zeMveliso
iveliso ezifakiwe
Ukwenziwa ngokwezifiso kweCable

I-LNG Terminal Header kunye neCryogenic Cable – I-CU/PEEK Cable 7mm² 0.6/1.0kV (6/10kV Ukhetho) Ukumelana nobushushu obuMthubi obuneMilo yesikwere 300°C

Intloko yesiphelo se-LNG yePrimiyamu kunye nentambo ye-cryogenic CU/PEEK 7mm² 0.6/1.0kV.

I-copper engenanto emile okwesikwere ebotshelelwe kakuhle, i-PEEK insulation etyheli. Imelana nobushushu obungama-300°C.

Cela isicatshulwa esineenkcukacha kunye nephepha ledatha!

  • Uhlobo lweCable Intambo ye-LNG Cryogenic PEEK CU/PEEK Isikwere seMilo
  • Iinkcukacha zeCable 7mm²
  • Umqhubi Ubhedu olungenanto (i-TC, i-CU, i-SPC, i-NPC ayinyanzelekanga)
  • Ulwakhiwo I-acc yentambo edibeneyo kwi-IEC 60228, iKlasi 5
  • Ukuvala ubushushu I-PEEK compound (i-FEP, i-PTFE, i-PFA, i-PI, i-PEEK ayinyanzelekanga)
  • Iicores Umongo omnye (emva kokuba uxinekile uba sisikwere)
  • I-Voltage elinganisiweyo 0.6/1kV
  • Ubushushu obulinganisiweyo ukuya kuthi ga kwi +300℃
  • Inombolo yeCable D515
  • Igama elingundoqo Intambo ye-LNG cryogenic
  • Isicelo ilungele i-LNG terminal header kunye ne-cryogenic

I-LNG Terminal Header kunye neCryogenic Cable – I-CU/PEEK Cable 7mm² 0.6/1.0kV (6/10kV Ukhetho) Ukumelana nobushushu obuMthubi obuneMilo yesikwere 300°C

Le ntambo ikhethekileyo ye-cryogenic yenzelwe ngokukodwa i-LNG terminal header kunye nezicelo zepompo ezingaphantsi komhlaba ezifakwe ngaphakathi kwiitanki ze-cryogenic LNG. Le ntambo inoyilo olukhethekileyo lwesikwere olune-conductor ye-7mm², elinganiswe kwi-0.6/1.0kV kunye noqwalaselo olukhethiweyo lwe-6/10kV olufumanekayo. Le ntambo yesikwere iphucula ukusetyenziswa kwendawo ngaphakathi kwenkqubo ye-LNG header kwaye iqinisekisa indawo efanelekileyo ngexesha lokufakwa.

Umqhubi usebenzisa ubhedu olungenanto olufakwe kakuhle, olubonelela ngokuguquguquka okugqwesileyo kokufakelwa kwiindawo eziguquguqukayo ngelixa lugcina amandla okuthwala amandla afanelekileyo. I-PEEK (Polyetheretherketone) insulation etyheli inika ukusebenza okugqwesileyo kumaqondo obushushu aguquguqukayo kwaye inika ukumelana nobushushu ukuya kuthi ga kwi-300°C, iqinisekisa ukusebenza okuthembekileyo kumanqanaba obushushu aphezulu ukusuka kwiimeko zokugcina i-LNG (-162°C) ukuya kuchaphazeleko oluphezulu lobushushu.

Le nkqubo yekhebula eguquguqukayo ye-cryogenic isetyenzisiwe ngempumelelo kwiiterminal ze-LNG ezingaphezu kwe-1,000 kunye neenqanawa ze-LNG/LPG ezingaphezu kwama-3,000 kwihlabathi liphela, nto leyo ebonisa ukuthembeka okuqinisekisiweyo kokunikezelwa kombane wepompo engaphantsi komhlaba kwizicelo ezifuna kakhulu i-cryogenic. Ukudibanisa i-conductor efakwe kakuhle kunye ne-PEEK insulation kuqinisekisa ukuguquguquka kokufakelwa kwiindawo ze-header zetanki eqinileyo ngelixa kubonelela ngokuqina kombane kunye noomatshini okufunekayo ekusebenzeni okuqhubekayo okungaphantsi komhlaba.

Ikhebula le-D515-LNG-PEEK-01.jpgIkhebula le-D515-LNG-PEEK-02.jpg

Iimpawu eziphambili kunye neenzuzo zobugcisa

  • Uyilo lwemilo yesikwere esiyi-7mm² ukuze kulungiselelwe i-LNG header

  • Uvavanyo lwe-0.6/1.0kV (ukhetho lwe-6/10kV kwiimfuno ze-voltage ephezulu)

  • Umqhubi wekopolo ongenanto oxineneyo ukuze kube lula ukuguquguquka kwe-cryogenic

  • PEEK insulation yellow ukuze kusebenze kakuhle kubushushu obugqithisileyo

  • Ukumelana nobushushu obuyi-300°C kunye nokukwazi ukucima i-cryogenic ukuya kwi--196°C

  • Ingqinwe kwiiterminal ze-LNG ezingaphezu kwe-1,000 kunye neenqanawa ze-LNG/LPG ezingaphezu kwe-3,000

  • Imilo yesikwere yenza kube lula ukusebenzisa indawo ngokufanelekileyo kwiintloko zetanki

  • Yenzelwe umbane wepompo engaphantsi kwamanzi kwiitanki ze-LNG ezicryogenic

Iinkcukacha kunye nolwakhiwo

Ipharamitha Iinkcukacha
Uhlobo Intloko yesiphelo se-LNG kunye nentambo ye-cryogenic
Uqwalaselo Umongo omnye, osisikwere
Ubungakanani bomqhubi 7mm²
Umqhubi Ubhedu olungenanto, oluxineneyo, olunemilo yesikwere
Ukuvala ubushushu I-PEEK (iPolyetheretherketone) compound, tyheli
Uvavanyo lweVoltage 0.6/1.0kV (ukhetho lwe-6/10kV)
Uluhlu lobushushu I-Cryogenic ukuya kwi-+300°C
Ukumelana nobushushu 300°C
Imilo Isikwere
Isicelo Umbane wepompo efakwe emanzini kwiitanki ze-LNG

Kutheni Ukhetha Le Cable ye-LNG Cryogenic

Le ntambo ikhethekileyo ye-cryogenic yimiphumo yamava eminyaka emininzi kwintsimi kwi-terminal ye-LNG kunye nokusetyenziswa kweenqanawa. Uyilo lwesikwere lulungiselelwe ngokukodwa iinkqubo ze-header ze-LNG, okuvumela ukupakisha okusebenzayo kunye nokubekwa rhoqo kwisakhiwo se-header yetanki. Ukufakelwa kwe-PEEK kubonelela ngokusebenza okungenakuthelekiswa nanto kumanqanaba obushushu obugqithisileyo ukusuka kwindawo yokugcina i-cryogenic LNG (-162°C) ukuya ekubonakalisweni kobushushu obuphezulu (300°C), kuqinisekisa ukusebenza okuthembekileyo phantsi kwazo zonke iimeko. Umqhubi we-copper ongenanto oxineneyo ugcina ukuguquguquka nokuba kumaqondo obushushu axineneyo, okwenza kube lula ukufakwa kwiindawo ezixineneyo zee-header zetanki ze-LNG. Ngokusetyenziswa okuqinisekisiweyo kwii-terminals ze-LNG ezingaphezu kwe-1,000 kunye neenqanawa ze-LNG/LPG ezingama-3,000 kwihlabathi liphela, le nkqubo ye-cable ibonakalise ukuthembeka okugqwesileyo kokunikezelwa kwamandla epompo engaphantsi kwamanzi.

Izicelo Eziqhelekileyo – Ukusombulula Imingeni Ebalulekileyo ye-LNG

  • Iimpompo ezifakwe emanzini ze-LNG Terminal:Ibonelela ngombane othembekileyo kwiimpompo ezifakwe ngaphakathi kwiitanki zokugcina i-LNG ezicryogenic

  • Iinqanawa zokuthwala i-LNG:Ihambisa uqhagamshelo lwamandla kwiinkqubo zepompo yemithwalo kwiinkampani ze-LNG/LPG

  • Izixhobo zokugcina i-LPG:Ibonelela ngeentambo ze-cryogenic kwiinkqubo zepompo zesiphelo se-LPG

  • Izityalo zokucheba ezinde:Ivumela ukusasazwa kwamandla kwiimpompo ze-LNG peak shaving facility

  • IiTerminali zokungenisa/zokuthumela ngaphandle:Ibonelela ngamandla okupompo athembekileyo kwiindawo zokwamkela nokulayisha i-LNG

  • Izixhobo ze-Floating LNG (FLNG):Ihambisa iintambo ze-cryogenic kwiinqanawa zemveliso kunye nezokugcina ze-FLNG

  • IiHubhu ze-LNG ezincinci:Ixhasa iinkqubo zokumpompa ze-LNG ezisasazwayo kunye neendawo zokusasaza

FAQ

Q1: Kutheni intambo yesikwere ichazwe kwii-LNG header applications?

A: Imilo yesikwere iphucula ukusetyenziswa kwendawo ngaphakathi kwenkqubo yentloko yetanki ye-LNG, iqinisekisa indawo ehambelanayo ngexesha lokufakwa, kwaye ivumela ukupakishwa kakuhle kweentambo ezininzi kwiindawo zentloko ezixineneyo.

Umbuzo 2: Yintoni eyenza i-PEEK insulation ifaneleke kwizicelo ze-cryogenic LNG?

A: I-PEEK igcina iipropati ezibalaseleyo zoomatshini nezombane ukusuka kumaqondo obushushu aqinileyo (-196°C) ukuya kumaqondo obushushu aphezulu (300°C), inokumelana okugqwesileyo kweekhemikhali kwi-LNG kunye nokuphuma kwegesi okuncinci.

Umbuzo 3: Kutheni kusetyenziselwa i-conductor efakwe kakuhle kwiintambo ze-cryogenic?

A: Ulwakhiwo oluxineneyo lugcina ukuguquguquka kumaqondo obushushu aqinileyo apho ii-conductors eziqinileyo ziba buthathaka, nto leyo eyenza kube lula ukufakwa kwiindawo ezixineneyo zetanki.

Q4: Ngowuphi umlinganiselo we-voltage ofumanekayo kule ntambo?

A: Umgangatho oqhelekileyo yi-0.6/1.0kV kwizicelo eziqhelekileyo zepompo engaphantsi kwamanzi, kwaye i-6/10kV yokuzikhethela iyafumaneka kwiimfuno eziphezulu zevolthi kwiindawo ezinkulu.

Umbuzo 5: Isasazwa kangakanani le nkqubo yekhebula?

A: Le nkqubo yekhebula e-cryogenic isetyenzisiwe ngempumelelo kwiiterminal ze-LNG ezingaphezu kwe-1,000 kunye neenqanawa ze-LNG/LPG ezingaphezu kwe-3,000 kwihlabathi liphela, nto leyo ebonisa ukuthembeka okuqinisekisiweyo kwentsimi.