Isihloko Sesiphetho se-LNG kanye Nekhebula Eliyi-Cryogenic – Ikhebula le-CU/PEEK 7mm² 0.6/1.0kV (6/10kV Ongakukhetha) Ukumelana Nokushisa Okuphuzi Okunesimo Esiyisikwele 300°C
Isihloko Sesiphetho se-LNG kanye Nekhebula Eliyi-Cryogenic – Ikhebula le-CU/PEEK 7mm² 0.6/1.0kV (6/10kV Ongakukhetha) Ukumelana Nokushisa Okuphuzi Okunesimo Esiyisikwele 300°C
Le khebula ekhethekile ye-cryogenic yenzelwe ngqo i-LNG terminal header kanye nezinhlelo zokusebenza zephampu ezifakwe ngaphakathi kwamathangi e-cryogenic LNG. Ikhebula linomklamo oyingqayizivele wesimo sesikwele one-conductor engu-7mm², ekalwe ku-0.6/1.0kV kanye nokulungiselelwa okungakhethwa kwe-6/10kV okutholakalayo. Isimo sesikwele senza ngcono ukusetshenziswa kwesikhala ngaphakathi kohlelo lwekhanda lethangi le-LNG futhi siqinisekisa indawo ehambisanayo ngesikhathi sokufakwa.
Umqhubi usebenzisa ukwakhiwa kwethusi elingenalutho eliboshwe kahle, okunikeza ukuguquguquka okuhle kakhulu kokufakwa ezindaweni ezi-cryogenic ngenkathi kugcinwa umthamo wokuthwala wamandla wamanje ofanele. Ukufakwa kwe-PEEK (Polyetheretherketone) okuphuzi kunikeza ukusebenza okuhle kakhulu emazingeni okushisa a-cryogenic futhi kunikeza ukumelana nokushisa okufika ku-300°C, okuqinisekisa ukusebenza okuthembekile kulo lonke izinga lokushisa elibi kakhulu kusukela ezimweni zokugcina ze-LNG (-162°C) kuya ekuvezweni okungenzeka kube khona kokushisa okuphezulu.
Lolu hlelo lwekhebula oluguquguqukayo oluguquguqukayo lusetshenziswe ngempumelelo kuma-terminal e-LNG angaphezu kuka-1,000 kanye nemikhumbi ye-LNG/LPG engaphezu kuka-3,000 emhlabeni jikelele, okubonisa ukuthembeka okuqinisekisiwe kokuhlinzekwa kwamandla epompo engaphansi kwamanzi ezinhlotsheni ze-cryogenic ezidinga kakhulu. Ukuhlanganiswa komqhubi oboshwe kahle kanye nokufakwa kwe-PEEK kuqinisekisa ukuguquguquka kokufakwa ezindaweni ze-header yethangi eliqinile ngenkathi kunikezwa ubuqotho bukagesi nobemishini obudingekayo ekusebenzeni okuqhubekayo okungaphansi kwamanzi.


Izici Eziyinhloko Nezinzuzo Zobuchwepheshe
-
Umklamo wesimo sesikwele esingu-7mm² wokwenza ngcono i-LNG header
-
Isilinganiso esingu-0.6/1.0kV (6/10kV uma uthanda izidingo ze-voltage ephezulu)
-
Umqhubi wethusi ongenalutho oboshwe kahle ukuze kube nokuguquguquka kwe-cryogenic
-
HLOLA okuphuzi kokushisa ukuze kusebenze kahle kakhulu ekushiseni
-
Ukumelana nokushisa okungu-300°C kanye nekhono le-cryogenic elifinyelela ku--196°C
-
Kufakazelwe kuma-terminal e-LNG angaphezu kwe-1,000 kanye nemikhumbi ye-LNG/LPG engaphezu kwe-3,000
-
Ukuma kwesikwele kwenza ukusetshenziswa kwesikhala okuphumelelayo ezihlokweni zethangi
-
Yakhelwe ukuphakelwa kwamandla epompo engaphansi kwamanzi emathangini e-LNG acwebezelayo
Imininingwane kanye nokwakhiwa
| Ipharamitha | Imininingwane |
|---|---|
| Uhlobo | Isihloko se-terminal se-LNG kanye nekhebula le-cryogenic |
| Ukucushwa | Ingaphakathi elilodwa, isimo sesikwele |
| Usayizi Womqhubi | 7mm² |
| Umqhubi | Ithusi elingenalutho, eliboshwe kahle, eliyisikwele |
| Ukuvikela | I-PEEK (i-Polyetheretherketone) compound, ephuzi |
| Isilinganiso se-Voltage | 0.6/1.0kV (6/10kV uma uthanda) |
| Ibanga Lokushisa | I-Cryogenic kuya ku-+300°C |
| Ukumelana Nokushisa | 300°C |
| Isimo | Isikwele |
| Isicelo | Ukunikezwa kwamandla epompo efakwe emanzini emathangini e-LNG |
Kungani Ukhethe Le Cable ye-LNG Cryogenic
Le ntambo ekhethekile ye-cryogenic iwumphumela weminyaka eminingi yolwazi lwasensimini kuzinhlelo ze-LNG terminal kanye nemikhumbi. Umklamo wesimo sesikwele wenzelwe ngqo izinhlelo ze-LNG header, okuvumela ukupakisha okuphumelelayo kanye nokubekwa okuhambisanayo ngaphakathi kwesakhiwo se-header yethangi. Ukufakwa kwe-PEEK kunikeza ukusebenza okungenakuqhathaniswa kulo lonke izinga lokushisa elibi kakhulu kusukela ekugcinweni kwe-cryogenic LNG (-162°C) kuya ekuvezweni kokushisa okuphezulu okungenzeka (300°C), okuqinisekisa ukusebenza okuthembekile ngaphansi kwazo zonke izimo. Umqhubi wethusi ongenalutho oboshwe kahle ugcina ukuguquguquka ngisho nasemazingeni okushisa e-cryogenic, okwenza kube lula ukufakwa ezindaweni ezivalekile zama-header ethangi le-LNG. Ngokusetshenziswa okuqinisekisiwe kuma-terminal e-LNG angaphezu kwe-1,000 kanye nemikhumbi ye-LNG/LPG engu-3,000 emhlabeni jikelele, lolu hlelo lwekhebula lubonise ukuthembeka okumangalisayo kokuhlinzekwa kwamandla ephampu engaphansi kwamanzi.
Izicelo Ezijwayelekile - Ukuxazulula Izinselele Ezibucayi ze-LNG
-
Amaphampu Angaphansi Kwe-LNG Terminal:Ihlinzeka ngogesi othembekile wamaphampu acwiliswe ngaphakathi kwamathangi okugcina e-LNG acwebezelayo
-
Imikhumbi Yokuthwala I-LNG:Iletha ukuxhumeka kwamandla kwezinhlelo zephampu yempahla kubaphathi be-LNG/LPG
-
Izindawo Zokugcina Izimpahla ze-LPG:Ihlinzeka ngezintambo ze-cryogenic zezinhlelo zephampu ye-LPG terminal
-
Izitshalo Zokushefa Eziphakeme:Ivumela ukusatshalaliswa kwamandla kwamaphampu esikhungo sokushefa se-LNG peak
-
Amatheminali Okungenisa/Ukuthumela:Inikeza amandla ephampu athembekile kuma-terminals okwamukela nokulayisha e-LNG
-
Izinsiza ze-Floating LNG (FLNG):Iletha izintambo ze-cryogenic zemikhumbi yokukhiqiza neyokugcina i-FLNG
-
Ama-LNG Hubs Amancane:Isekela izinhlelo zokuphampa zesitoreji se-LNG esisatshalalisiwe kanye nezindawo zokusabalalisa
- Cela Idatha Yesampula Nokuhambisana Nemithetho - Hlola ikhebula kuhlelo lwakho lokusebenza
-
Landa Imininingwane Yobuchwepheshe - Thola idatha ephelele yokusebenza kagesi
-
Xhumana neThimba Lethu Lobunjiniyela - Xoxa ngezidingo zakho zokuxhuma izintambo zikagesi
-
Thola Isilinganiso Sokuncintisana - Izixazululo ze-OEM/ODM ziyatholakala



Imibuzo Evame Ukubuzwa
Q1: Kungani ikhebula elinomumo oyisikwele lichazwe kuzinhlelo zokusebenza zekhanda le-LNG?
A: Ukuma kwesikwele kuthuthukisa ukusetshenziswa kwesikhala ngaphakathi kohlelo lwe-header yethangi le-LNG, kuqinisekisa ukubekwa okulinganayo ngesikhathi sokufakwa, futhi kuvumela ukupakishwa kahle kwezintambo eziningi ezindaweni ze-header ezivalekile.
Umbuzo 2: Yini eyenza ukufakelwa kwe-PEEK kufane nokusetshenziswa kwe-LNG ecryogenic?
A: I-PEEK igcina izakhiwo ezinhle kakhulu zemishini kanye nogesi kusukela emazingeni okushisa acwebezelayo (-196°C) kuya emazingeni okushisa aphezulu (300°C), ngokumelana okungavamile kwamakhemikhali ne-LNG kanye nokuphuma kwegesi okuphansi.
Umbuzo 3: Kungani kusetshenziswa i-conductor eboshwe kahle kumakhebula e-cryogenic?
A: Ukwakhiwa okugoqekile kahle kugcina ukuguquguquka emazingeni okushisa acwebezelayo lapho ama-conductor aqinile eba buthakathaka khona, okwenza kube lula ukufakwa ezindaweni eziqinile zethangi.
Q4: Yisiphi isilinganiso samandla kagesi esitholakalayo sale ntambo?
A: Isilinganiso esijwayelekile singu-0.6/1.0kV kwezicelo ezijwayelekile zephampu engaphansi kwamanzi, kanti i-6/10kV yokuzikhethela iyatholakala ngezidingo ze-voltage ephezulu ekufakweni okukhulu.
Umbuzo 5: Lolu hlelo lwekhebula lusetshenziswa kabanzi kangakanani?
A: Lolu hlelo lwekhebula eli-cryogenic lusetshenziswe ngempumelelo kuma-terminal e-LNG angaphezu kwe-1,000 kanye nemikhumbi ye-LNG/LPG engaphezu kwe-3,000 emhlabeni jikelele, okubonisa ukuthembeka kwensimu okuqinisekisiwe.