Premium high temperature measuring cable Type K extension KX 2x0.20mm² laid flat.

NiCr/NiSr 7/0.19 conductors, PFA insulation red/white, PFA sheath blue. 300/500V 250°C.

Request a detailed quote & datasheet!

  • Cable Type Type K extension cable PFA/PFA
  • Cable Spec 2x0.20mm²
  • Conductor NiCr(+) & NiSr(-)
  • Construction Stranded wire 7/0.19
  • Insulation PFA perfluoroalkoxy compound red(+) & white(-) (FEP, PTFE, PFA, PI, PEEK optional)
  • Pairs 2cores laid flat
  • Sheath PFA perfluoroalkoxy compound (FEP, PTFE, PFA, PI, PEEK optional) black
  • Rated Voltage 300/500V
  • Rated Temperature -60℃ to +250℃
  • Cable No. D399
  • Keyword KX flat thermocouple wire
  • Application ideal for temperature measuring range 0-200℃

High Temperature Measuring Cable – Type K Extension Cable KX PFA/PFA 2x0.20mm² Laid Flat 300/500V 250°C, Conductor: NiCr (+) & NiSr (-) 7/0.19, Insulation: PFA Compound Red (+) & White (-), 2 Cores Laid Flat, Sheath: PFA Compound Blue, Outer Dimensions: 3.3 x 2.4mm

This high temperature measuring cable features Type K extension grade (KX) construction specifically engineered for accurate temperature measurement from 0°C to 200°C with 250°C cable rating. The conductors utilize NiCr (Nickel-Chromium) for positive and NiSr (Nickel-Silicon) for negative with 7/0.19 fine-strand construction, providing excellent flexibility and thermoelectric accuracy for Type K thermocouple systems. PFA insulation in red (+) and white (-) offers exceptional thermal stability, chemical resistance, and dielectric properties at 250°C continuous operation while providing clear polarity identification. The two cores are laid flat for space-saving installation in confined areas and consistent thermal contact. The blue PFA outer sheath delivers superior chemical resistance, thermal stability, and durability with a distinctive color for easy cable identification. Rated at 300/500V with compact 3.3 x 2.4mm flat profile, this cable is ideal for high temperature measurement applications requiring reliable Type K signal transmission in demanding environments.

d399-type-k-2x0.2mm2-laid-flat-300-500v-pfa-high-temperature-cable-02.jpgd399-type-k-2x0.2mm2-laid-flat-300-500v-pfa-high-temperature-cable-03.jpg

Thermocouple Type

Thermocouple Type Conductor Type Temperature Range °F Standard Limits Special Limits
T Copper (+) vs Constantan (-) -330 °F to -85 °F ± 1.5% ± 0.8%
-85 °F to +270 °F ± 1.8 % ± 0.9 °F
+270 °F to +660 °F ± 0.75% ± 0.4%
J Iron (+) vs Constantan (-) +32 °F to +545 °F ± 0.4% ± 2 °F
+545 °F to +1400 °F ± 0.75% ± 0.4%
E Chromel (+) vs Constantan (-) -300 °F to -270 °F ± 1% ± 1.8 °F
-270 °F to +480 °F ± 3 °F ± 1.8 °F
+480 °F to +640 °F ± 3 °F ± 0.4%
+640 °F to +1600 °F ± 0.5% ± 0.4%
K Chromel (+) vs Alumel (-) -330 °F to -165 °F ± 2% ± 1%
-165 °F to +32 °F ± 4% ± 2 °F
+32 °F to +545 °F ± 4 °F ± 2 °F
+545 °F to +2300 °F ± 0.75% ± 4%
N* Nicrosil (+) vs Nisil (-) + 32 °F to +545 °F ± 4 °F ± 2 °F
+ 454 °F to +2300 °F ± 0.75% ± 4%
S Platinum -10% +32 °F to +1110 °F ± 2.7 °F ± 0.1%
Rhodium (+) vs Platinum (-) +1110 °F to +2650 °F ± 0.25% ± 0.1%
R Platinum -13% +32 °F to +1110 °F ± 2.7 °F ± 1.1 °F
Rhodium (+) vs Platinum (-) +1110 °F to +2650 °F ± 0.25% ± 0.1 %
W* Platinum -30% +1600 °F to +3100 °F ± 1%  
Rhodium (+) vs Platinum -6%
Rhodium (-)
W3 Tungsten -3% +800 °F to +4200 °F ± 1%  
Rhenium
Tungsten -25%
Rhenium (-)
W3 Tungsten (+) vs Tungsten -26% +800 °F to +4200 °F ± 1%  
Rhenium (-)
W5* Tungsten -5% +800 °F to +4200 °F ± 1%  
Rhenium (+) vs Tungsten -26%  
Rhenium (-)  

D349 thermocouple cable color code.jpgD349-thermocouple cable temeprature range.png

Key Features & Technical Advantages

  • Type K extension grade (KX) for accurate temperature measurement

  • NiCr (+) and NiSr (-) conductors with 7/0.19 stranding for flexibility

  • PFA insulation red (+) and white (-) for clear polarity identification

  • Flat construction for space-saving installation

  • PFA sheath blue for chemical resistance and cable identification

  • 250°C continuous temperature rating

  • 300/500V voltage rating

  • Compact flat profile: 3.3 x 2.4mm

  • Excellent chemical resistance and thermal stability

Specifications & Construction

Parameter Details
Type KX Type K extension cable
Configuration 2 x 0.20mm² laid flat
Conductor (+) NiCr (Nickel-Chromium), 7/0.19
Conductor (-) NiSr (Nickel-Silicon), 7/0.19
Insulation PFA compound, red (+) / white (-)
Core Arrangement 2 cores laid flat
Sheath PFA compound, blue
Voltage Rating 300/500V
Temperature Rating 250°C continuous
Outer Dimensions 3.3 x 2.4mm
Application 0-200°C temperature measurement

Why Choose Our Type K Extension Flat Cable

We specialize in high temperature thermocouple cables for precision measurement applications. This KX flat design combines NiCr/NiSr conductors with PFA insulation for accurate Type K signal transmission up to 250°C. The 7/0.19 fine-strand construction provides flexibility for installation in confined spaces. Clear polarity identification with red/white insulation eliminates connection errors. Flat profile enables space-saving routing in equipment and control panels. Blue PFA sheath offers excellent chemical resistance and easy cable identification. As a specialized manufacturer, we control all production stages, offering custom lengths and technical support for your specific temperature measurement requirements.

Typical Applications – Solving Critical Temperature Measurement Challenges

  • Industrial Process Control: Provides accurate Type K temperature measurement for ovens, furnaces, and heat treatment equipment

  • Plastic Molding Machinery: Delivers reliable thermocouple connections for barrel zone temperature monitoring

  • Packaging Equipment: Enables precise temperature control for heat sealing and shrink tunnel applications

  • Laboratory Furnaces: Supports high temperature measurement in research and testing furnaces

  • Food Processing: Provides sanitary temperature monitoring for cooking, baking, and sterilization equipment

  • HVAC Systems: Delivers reliable temperature sensing for building automation and environmental control

  • Automotive Testing: Supports temperature measurement in engine test cells and component development

FAQ

Q1: What is the difference between thermocouple grade and extension grade Type K cable?

A: Extension grade (KX) uses similar but more economical alloys for connections from the probe to instrumentation, suitable for 0-200°C measurement range without exposure to process temperatures.

Q2: Why are NiCr and NiSr conductors used for Type K?

A: NiCr (Nickel-Chromium) and NiSr (Nickel-Silicon) provide accurate thermoelectric characteristics for Type K thermocouple systems with excellent stability at high temperatures.

Q3: What is the advantage of flat cable construction?

A: Flat profile allows space-saving installation in confined areas, consistent thermal contact, and simplified routing in equipment and control panels.

Q4: What does the red/white color coding indicate?

A: Red (+) and white (-) per international standards for Type K thermocouple extension cable, ensuring correct polarity connection every time.

Q5: What temperature rating does this cable achieve?

A: 250°C continuous for the PFA insulation and sheath, suitable for measurement applications up to 200°C with adequate safety margin.